It arrived today. Toggling the 4th SW2 switch on the motherboard immediately eliminated the problem on both servers. NOTE: The system management driver must be installed for the internal system health LED to provide pre-failure and warranty conditions. PCI Riser Interlock Fail Community ProLiant Servers (ML,DL,SL) CommunityCategoryBoardUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type. have a peek here

Sign up! The server worked when I got it, it was then changed from a rack mount to a stand alone and since then I've had misc interlock error.Problem is, I can't see where the problem is. I have another server just like this, and it works with the case open. Only 1 power suppy installed (right one as viewed from the rear)Set your system board switches to:SW1 2ON, all others offSW2 3ON, all others offSW3 ALL OFFConnect VGA Monitor, KB and Mouse directly to the system.Connect a known good network cable to iLO port. additional hints

So I'm confused on why/how you are getting the decode LEDS, since a) no DC power has been applied to the system to initiate POST and b) the switches should not be in decode mode. They sat in this state for a month or so and upon their intial startup, we received this error on two boxes. Everything seems to be "on" except the CPU fans and I don't think the hdd's are spinning.

At least they don’t AFTER they install two power supplies in a system specifically configured for a single power supply. it's always just amber. Any ideas or is that not what the Interlock light means?? 0 Kudos Reply All Forum Topics Previous Topic Next Topic 2 REPLIES Janine Bertolo Honored Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎08-18-2003 04:54 AM ‎08-18-2003 04:54 AM Re: Proliant DL380 Interlock Light Hello;The interlock light means the riser is not seated...They are famous for seeming to fit snugly and still being loose. I finally got around to ordering another backup DL 360 G3 last week off eBay.

cable but all cables are accounted for and connected.The person that owned it before is talking about "micro-switches" and how during the conversion betweem rack-mount and floor-mount some of these might have been disturbed.Thank you. 0 Kudos Reply Robin_37 Trusted Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎12-14-2004 08:53 PM ‎12-14-2004 08:53 PM Re: Interlock error According to my knowledge the following switch settings are available in the PL6500 pentium pro board, System Maintenance Switch Internal/External Battery Switch Hot Spare Boot Switch Processor Board - SW3 Processor Board - SW4 & SW5 System InterLock Switches And in the pentium Xeon the followingProcessor Core Frequency Switches Maintenance Configuration Switches (SW1) System InterLock Switches Regards 0 Kudos Reply The opinions expressed above are the personal opinions of the authors, not of Hewlett Packard Enterprise. So by the general laws of armchair logic, I knew this was no longer a problem with the hardware. I'm not sure what 85 codes you are referring to... They all come on.ALso, the green power light does not come on in the back of my powersupplies (both!).

I have also switched the riser card with another server and still the same issue. There has to be something else. I reseated CPU’s, CPU power boards, RAM, power supplies and anything else that remotely looked removable. I think it is either CR12 or CR13.

Is that true? do you mean mother board part number? 305439-001 is the mobo...It was working before i had it shipped to my new address. Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking Servers and Operating Systems Software Services Storage Company Careers Corporate Responsibility Events Hewlett Packard Labs Partner Certification Partner Solutions Welcome Welcome Announcements Tips and Tricks Feedback Blogs All About the Apps Alliances Around the Storage Block Backup and Governance Behind the scenes @ Labs Big Data Cloud Source Coffee Coaching Converged Data Center Infrastructure Discover Insider Enterprise Services Grounded in the Cloud HPE Business Insights HPE Careers Infrastructure Insights Inspiring Progress Internet of Things (IoT) Solutions from HPE IT Operations Management (ITOM) IT Service Management LoadRunner and Performance Center My Learning Certification Networking OEM Solutions Protect Your Assets Security Research Servers: The Right Compute Software Developers Software Solutions Technical Support Services Telecom IQ Transforming IT UK Public Sector Voice of the Customer – Interviews by Dana Gardner Quick Links Community FAQ Community FAQ - Quick Start FAQ - Registration and Logging In FAQ - Community Search FAQ - Blogs FAQ - Kudos FAQ - Accepted Solutions FAQ - Images and Image Galleries FAQ - Tagging FAQ - Bookmarks, Subscriptions, and RSS FAQ - Personalize Your Account Settings FAQ - Private Messenger Community Guidelines Contact Us Community FAQ - Quick Start Ranking Overview Rules of Participation Tell us what you think HPE Developer Community HPE Live Network Content Marketplace HPE Software Support Online HPE Support Center Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking Servers and Operating Systems Software Services Storage Company Careers Corporate Responsibility Events Hewlett Packard Labs Partner Certification Partner Solutions Welcome Welcome Announcements Tips and Tricks Feedback Blogs All About the AppsAlliancesAround the Storage BlockBackup and GovernanceBehind the scenes @ LabsBig DataCloud SourceCoffee CoachingConverged Data Center InfrastructureDiscover InsiderEnterprise ServicesGrounded in the CloudHPE Business InsightsHPE CareersInfrastructure InsightsInspiring ProgressInternet of Things (IoT) Solutions from HPEIT Operations Management (ITOM)IT Service ManagementLoadRunner and Performance CenterMy Learning CertificationNetworkingOEM SolutionsProtect Your AssetsSecurity ResearchServers: The Right ComputeSoftware DevelopersSoftware SolutionsTechnical Support ServicesTelecom IQTransforming ITUK Public SectorVoice of the Customer – Interviews by Dana Gardner Quick Links Community FAQ Community FAQ - Quick Start FAQ - Registration and Logging In FAQ - Community Search FAQ - Blogs FAQ - Kudos FAQ - Accepted Solutions FAQ - Images and Image Galleries FAQ - Tagging FAQ - Bookmarks, Subscriptions, and RSS FAQ - Personalize Your Account Settings FAQ - Private Messenger Community Guidelines Contact Us Community FAQ - Quick Start Ranking Overview Rules of Participation Tell us what you think HPE Developer Community HPE Live Network Content Marketplace HPE Software Support Online HPE Support Center Log In English English Deutsch Español Française Italiano 한국어 日本語 Norsk Português Русский 简体中文 繁體中文 New Post Interlock LED lighted up in red. In normal operations, all of the LEDs are off unless one of the components fails.

The recyclers clearly acquired these units as single power supply, tested them, then loaded up the additional power supply under the assumption it would be auto-detected. http://orgias.org/hp-proliant/hp-proliant-ml350-error.html When removing the access panel to view the Systems Insight Display LEDs (on The system management driver must be installed for the internal system health LED to Component Power supply (primary) Power supply (optional) Processor memory module board System board System NMI switch Expansion slot System board Processor power module DIMM slot Processor Fan Component identification 16 Previous page Next page 1...121314151617181920 Also See for HP DL585 - ProLiant - G2 HP BL685c - ProLiant - 4 GB RAM Datasheet 313 pages HP DL585 User Manual 183 pages HP ProLiant DL585 Maintenance And Service Manual 112 pages Related Manuals for HP DL585 - ProLiant - G2 Server HP ProLiant DL585 User Manual Generation 6 (106 pages) Server HP ProLiant DL585 User Manual Generation 6 (106 pages) Server HP ProLiant DL585 Quickspecs Generation 7 (57 pages) Computer Hardware HP DL585 Overview Hp proliant generation 2(g2) (47 pages) Server HP ProLiant DL585 Quickspecs Generation 5 (47 pages) Network Card HP ProLiant DL585 Specification Hp network adapter quickspecs (45 pages) Server HP ProLiant BL30p User Manual Hp insight management wbem providers for windows server 2003 and windows server 2008 user guide (41 pages) Desktop HP DL585 - ProLiant - G2 Supported Configurations Implementing microsoft windows server 2008 service pack 2 on hp servers (26 pages) Desktop HP DL585 - ProLiant - G2 Introduction Manual The amd processor roadmap for industry-standard servers, 6th edition (15 pages) Server HP ProLiant DL140 - G2 Server Introduction Manual Critical factors in intra-rack power distribution planning for high-density systems (13 pages) Desktop HP DL585 - ProLiant - G2 Introduction Manual Hp proliant dl585 g2 server technology (11 pages) Desktop HP DL580 - ProLiant - G4 Installation Instructions Manual 3-7u quick deploy rail system installation instructions (10 pages) Related Content for HP DL585 - ProLiant - G2 DL385 - ProLiant - G5 Systems Insight Display Leds HP DL385 - ProLiant - G5 DL370 - ProLiant - G6 Performance Systems Insight Display Leds HP DL370 - ProLiant - G6 Performance DL385 - ProLiant - G5 Systems Insight Display Cabling HP DL385 - ProLiant - G5 P6000 Single Sign-on From Hp Systems Insight Manager HP P6000 BladeSystem bc2000 - Blade PC Integration With The Hp Systems Insight Manager Utility HP BladeSystem bc2000 - Blade PC Rx2620-2 - Integrity - 0 MB RAM Installing Licenses Using The Systems Insight Manager (sim) License Manager HP Rx2620-2 - Integrity - 0 MB RAM DL385 - ProLiant - G5 Hp Systems Insight Manager HP DL385 - ProLiant - G5 BL2x220c - ProLiant - G5 Server A Hp Systems Insight Manager HP BL2x220c - ProLiant - G5 Server A Rx2620-2 - Integrity - 0 MB RAM Hp Systems Insight Manager Task HP Rx2620-2 - Integrity - 0 MB RAM Blade bc1000 Hp Systems Insight Manager HP Blade bc1000 Blade bc1500 Hp Systems Insight Manager HP Blade bc1500 BL685c - ProLiant - 4 GB RAM Insight Display HP BL685c - ProLiant - 4 GB RAM Xw460c - ProLiant - Blade Workstation Hp Bladesystem Insight Display Components HP Xw460c - ProLiant - Blade Workstation Comments to this Manuals Your Name Enter your comment: Symbols: 0 Enter text from picture: Write a comment Latest comments: × Bookmark × Please, turn your attention By pressing 'print' button you will print only current page. Any remedy to this?Thanks and Regards,Michael 0 Kudos Reply All Forum Topics Previous Topic Next Topic 1 REPLY JohnWRuffo Honored Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎09-29-2004 12:33 AM ‎09-29-2004 12:33 AM Re: Interlock LED lighted up in red. and PPM is in correct slot.(2) still nothing in iLo..

All the cables are accounted for, all the system boards have been removed and replaced and there's still an interlock error.If I ask my friend he says something about "micro-switches" along the chassis that might have been flipped when it was changed and they need to be flipped back. http://bizsupport2.austin.hp.com/bc/docs/support/SupportManual/c01125247/c01125247.pdf There's also an LED table to help isolate. Also, I can not turn the server on.. http://orgias.org/hp-proliant/hp-proliant-ppm-error.html Inside the server showed only an amber Interlock light.

The green lights don't come on in the back.. LED Component PS1 Power supply (primary) PS2 Power supply (optional) CPU BD (Power Fault) Processor memory module board I/O BD System board NMI System NMI switch SLOT X Expansion slot CPU BD (Interlock Error) System board PPM X Processor power module 1A–32D DIMM slot PROC X Processor FAN X Fan See the HP ProLiant DL585 Generation 2 Server Maintenance and Service Guide on the Documentation CD for more information. The power supplies didn’t even light their green LEDs despite hearing the fans spin inside.

Opening up the case, i can see an amber light on the PCI Riser Interlock Fail.

By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner ProgramsSocialSocialLinkedInFacebookTwitterYouTubeCommunitiesCommunitiesDeveloper ForumsEnterprise BusinessCustomer ResourcesCustomer ResourcesEnterprise StorePublic Sector StoreEducation and TrainingEmail SignupLegalLegalPrivacyTerms of UseCookies © Copyright 2016 Hewlett Packard Enterprise Development LP Skip to ContentSkip to FooterSolutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility Infrastructure Internet of Things Small and Medium Business Service Providers All Solutions Services Advise, Transform and Manage Financing and Flexible Capacity IT Support Services Education and Training Services All Services Products Integrated Systems Composable Systems Converged Systems Hyper Converged Systems Blade Systems Infrastructure Management Software Application Lifecycle Management Application Delivery Management Big Data Analytics DevOps Enterprise Security Hybrid and Private Cloud Information Governance Information Management IT Service Management Operations Management Server Management Software as a Service (SaaS) Software-Defined Data Center Storage Management All Software Servers Rack Servers Tower Servers Blade Servers Density Optimized Mission Critical Servers Servers for Cloud Server Management All Servers Storage All-flash and Hybrid Storage Midrange and Enterprise Storage Entry Storage Systems Data Availability, Protection and Retention Software Defined Storage Management and Orchestration Storage Networking All Storage Networking Switches Routers Access Points and Controllers Wireless LAN Campus and Branch Networking Data Center Networking Wide Area Network Software Defined Networking Network Functions Virtualization Network Management All Networking About UsSupportClearType to search2086159Solutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility Infrastructure Internet of Things Small and Medium Business Service Providers All Solutions Services Advise, Transform and Manage Financing and Flexible Capacity IT Support Services Education and Training Services All Services Products Integrated Systems Composable Systems Converged Systems Hyper Converged Systems Blade Systems Infrastructure Management Software Application Lifecycle Management Application Delivery Management Big Data Analytics DevOps Enterprise Security Hybrid and Private Cloud Information Governance Information Management IT Service Management Operations Management Server Management Software as a Service (SaaS) Software-Defined Data Center Storage Management All Software Servers Rack Servers Tower Servers Blade Servers Density Optimized Mission Critical Servers Servers for Cloud Server Management All Servers Storage All-flash and Hybrid Storage Midrange and Enterprise Storage Entry Storage Systems Data Availability, Protection and Retention Software Defined Storage Management and Orchestration Storage Networking All Storage Networking Switches Routers Access Points and Controllers Wireless LAN Campus and Branch Networking Data Center Networking Wide Area Network Software Defined Networking Network Functions Virtualization Network Management All Networking About UsSupport Start of content Community Home > Servers and Operating Systems > ProLiant > ProLiant Servers > Interlock LED lighted up in red. I am using hotpluggable power supplies, so I put flipped switch 4 on SW1.I have reseated everything on the board.. by calculating the PAL leds to binary:1100000 == 0xC0 which.. I think they are labeled cr25 and cr26 ...

IMPORTANT: When removing the access panel to view the Systems Insight Display LEDs (on page 16 ), leave the server powered on. I get some action on the top 2 iLO diagnostic LEDs... (farthest from power supply). Hide thumbs Also See for DL585 - ProLiant - G2 User manual - 183 pagesMaintenance and service manual - 112 pagesQuickspecs - 57 pages 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 Systems Insight Display LEDs The front panel health LEDs indicate only the current hardware status. http://orgias.org/hp-proliant/hp-proliant-error-codes.html May 2011 22:13 Well it just goes to show you are never done learning in the IT business.

Don't show me this message again. The System Insight Display LEDs identify components experiencing an error, event, or failure. was not found on this server. Manuals Directory ManualsDir.com - online owner manuals library Search Directory Brands HP manuals Computer hardware ProLiant DL585 G2 Server Manual Systems insight display leds – HP ProLiant DL585 G2 Server User Manual Page 16 Text mode Original mode 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 Advertising Component identification 16 Systems Insight Display LEDs The front panel health LEDs indicate only the current hardware status.

Make sure the floppy and CD-ROM drives are firmly seated in their slots.Make sure the cabling for the SmartArray 5i are solid.There is a poster on the top cover showing all the components... But nothing I did resolved the seemingly dead server. I just basically want to know how to troubleshoot for a bad component.