Posting Guidelines Promoting, selling, recruiting, coursework and thesis posting is forbidden.Tek-Tips Posting Policies Jobs Jobs from Indeed What: Where: jobs by Link To This Forum! I would call up the parts place I referred to earlier in the thread and ask for a fan that has a pinout like I described. All rights reserved.Unauthorized reproduction or linking forbidden without expressed written permission. It was in looking over it I realized there was a second fan hidden from view behind the I/O bays, accessible only by removing the top cover.Here is the link to the docs for you or anyone else who may need it:http://www.compucanjes.com/manuales/c01132693.pdfYou guys are the greatest. have a peek here

Can a GM prohibit players from using external reference materials (like PHB) during play? The computer still comes up with the 1611: Cpu Fan failure detected message.I went onsite, and brought the computer back to the shop for further diagnosis, which is where i reseated everything under the sun.All the fans work, but i didnt like this micky mouse getup they did with the corner-store fan. I'm not sure if a fan failure in the I/O section would be critical so it may not generate the 1611 error if an I/O fan was missing or faulty in that area.You could possibly take the manufacturers details (make and model) from one of the fans and see if it can be purchased individually as HP don't make the actual fans.As a last resort you might be able to solder two wiring harnesses together from one working fan pair and plug the cables into two sockets to fool the system into thinking all fans are OK but you run the risk of damaging another fan set doing this.I hope this helps.Brian 0 Kudos Reply Brian_Murdoch Honored Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎10-26-2007 09:25 PM ‎10-26-2007 09:25 PM Re: DL360 G3 - error 1611 CPU fan failure Hi,If it is possible to use the I/O fan as a substitute in the processor fan area, you may be able to get the I/O fan assembly cheaper if you need to buy one.The HP Spare Part number is 307525-001.If you look at the attached image you can see clearly that the fans are manufactured by NIDEC so again you may be able to use the NIDEC part number to obtain a fan.Try simply removing one of the I/O fans and plugging it into the socket for the processor fan which is faulty. Weeks ago it stopped booting with an error of Fan Solution Not Sufficient.

Advisory: (Revision) Integrated Lights-Out 2 (iLO 2) And iLO 2 Management Controller Driver - FIRMWARE/ DRIVER UPGRADE REQUIRED: ProLiant Server May Unexpectedly Reboot And Display Event ID 57 Error Messages - c01802766 - HP Business Support Center Quote: SUPPORT COMMUNICATION - CUSTOMER ADVISORY Document ID: c01802766 Version: 8 Advisory: (Revision) Integrated Lights-Out 2 (iLO 2) And iLO 2 Management Controller Driver - FIRMWARE/ DRIVER UPGRADE REQUIRED: ProLiant Server May Unexpectedly Reboot And Display Event ID 57 Error Messages NOTICE: The information in this document, including products and software versions, is current as of the Release Date. Back to top #6 adaniel adaniel Topic Starter Members 203 posts OFFLINE Local time:12:31 PM Posted 26 August 2010 - 02:27 AM dc3, thanks for all your help. I had seen the article you refenced and verified the replacement fan was identical to the failed one. It was client with old setup 0 Anaheim OP emajin May 30, 2014 at 10:05 UTC I ended up using a barebones of the same model and swapped the HDDs to get it going for now.

We use data about you for a number of purposes explained in the links below. Can I switch between two users in a single click? I removed the fan and put it in the first machine, but still get fan error and at a certain point in the SCO OpenServer bootup, it fails and shuts down. longsta PC Gaming Support 36 02-20-2011 05:49 PM adding Application server to network Hello, I have a dl380 g5 it has terminal server running on it and ad, it is also our applications server, it is running server 2003, SAP accounting software and it is also our file server, so I am going to add a couple server to the mix.

Not the answer you're looking for? Family and loved ones will always be a priority in my daily life. The amber LED is a further indication that the fan isn't being detected. I have a gateway gt5628, it came stock with a nvidia 8500 and, my computer used to run wow on ultra settings except...

After I replaced the CPU fan I had just I/O fan failure. Power the server off. RE: "1611 CPU Fan Failure" bootup error atlantisnet (ISP) 27 May 05 11:11 Cgull, who did you buy your replacement fan from?Do they have a specific model number for the fan with the correct wires?If so, what is it? You may also want to try a full firmware update for your selected OS to make sure that you're not affected by a BIOS bug.

Is it a G1, G2, G5, etc? http://www.tek-tips.com/viewthread.cfm?qid=338717 Luis RE: "1611 CPU Fan Failure" bootup error mousseman (MIS) 27 Aug 02 05:32 Have you tried to power up the machine with the panel off so you can see wether the fan is powering up? But still I receive this message.You say you put the connector of the fan in another plug... Most of my G3 servers died near 5 or 6 years of service.

Hi I was wondering if anybody here can help me with this server. navigate here Family and loved ones will always be a priority in my daily life. If I plug the old fan back in, noisey as it is, it still works and the machine will boot. RE: "1611 CPU Fan Failure" bootup error blexmark (TechnicalUser) 5 Aug 05 11:48 I was wondering if anyone found out a way to bypass the enviromental shutdown?I replaced the fan required, it NOW works but I don't have a management (yellow) cable on the fan.

If multiple classes have a static variable in common, are they shared (within the same scope?) "prohibiting" instead of "prohibit"? RE: "1611 CPU Fan Failure" bootup error Cgull (IS/IT--Management) 27 May 05 11:26 Atlantisnet, I got mine from shopspares.com.If you call and ask for Andy at 877-271-5356, mention Mike Siegel and this fan issue and he'll know exactly what you're talking about.The problem with this whole issue is that we discovered that the Compaq part number 122633 is the same for many slightly different fans.And as Andy told me, when you order this fan you generally never specify beyond the part number.They will assumably all spin, but my guess is only the ones with the 3 black, 1 red, and 1 yellow wires going to the pin connector will register the state of the CPU fan in POST. Plausibility of the Japanese Nekomimi more hot questions question feed about us tour help blog chat data legal privacy policy work here advertising info mobile contact us feedback Technology Life / Arts Culture / Recreation Science Other Stack Overflow Server Fault Super User Web Applications Ask Ubuntu Webmasters Game Development TeX - LaTeX Programmers Unix & Linux Ask Different (Apple) WordPress Development Geographic Information Systems Electrical Engineering Android Enthusiasts Information Security Database Administrators Drupal Answers SharePoint User Experience Mathematica Salesforce ExpressionEngine® Answers Cryptography Code Review Magento Signal Processing Raspberry Pi Programming Puzzles & Code Golf more (7) Photography Science Fiction & Fantasy Graphic Design Movies & TV Music: Practice & Theory Seasoned Advice (cooking) Home Improvement Personal Finance & Money Academia more (8) English Language & Usage Skeptics Mi Yodeya (Judaism) Travel Christianity English Language Learners Japanese Language Arqade (gaming) Bicycles Role-playing Games Anime & Manga more (18) Mathematics Cross Validated (stats) Theoretical Computer Science Physics MathOverflow Chemistry Biology Computer Science Philosophy more (3) Stack Apps Meta Stack Exchange Area 51 Stack Overflow Careers site design / logo © 2016 Stack Exchange Inc; user contributions licensed under cc by-sa 3.0 with attribution required rev 2016.10.18.4101 Server Fault works best with JavaScript enabled current community blog chat Server Fault Meta Server Fault your communities Sign up or log in to customize your list. http://orgias.org/hp-proliant/hp-proliant-ppm-error.html HP ProLiant DL360 G3 Server error 1611 thermal shutdown This is a discussion on HP ProLiant DL360 G3 Server error 1611 thermal shutdown within the Windows Servers forums, part of the Tech Support Forum category.

Its not likely that you replaced the fan in the front behind the IMD panel, and if you did then you replaced the wrong fan. Are you aComputer / IT professional?Join Tek-Tips Forums! Is a Union Member's Destructor Called Meaning of grey and yellow/brown colors of buildings in google maps?

The front of the case is blinking amber for fans, is there another location besides the 4 system fans I am missing?

But short of that, contact support. Click here to Register a free account now! That, after years of buying their products. Linked 20 Best sysadmin WTF?

Red Flag This Post Please let us know here why this post is inappropriate. RE: "1611 CPU Fan Failure" bootup error Cgull (IS/IT--Management) 26 May 05 14:22 I just had this issue with replacing a fan in a Proliant 800. The other is to check the thermal sensors to be sure that they are working properly. this contact form What is the name of this bush with red fruits?

Almost every time I try to do something on the internet my page is getting redirected to something else! The front panel indicating that fans 3 and 4 were down though both these fans are still in operation (and switching the fans does nothing).