Home > Error Codes > Hp Storageworks Msl4048 Error Codes

Hp Storageworks Msl4048 Error Codes

Contents

Update the firmware to the latest version. The Current command provides information for factory use only. The text after the main error code (Robotic controller generic problem in this example) is the text description for the error code. sub-code 00: drive sled #1, sub-code 01: drive sled #2 NOTE: Sled is the part of the robotics assembly that moves the robot towards the OCP or back towards the drive. Check This Out

Run the wellness test. 8E Ends of gripper movement not in expected range Run the wellness test 8F Ends of slider movement not in expected range Early firmware versions were not able to use as much force to get or place media in a magazine. The device displays a robot move error if the shipping lock is not removed. The text after the error sub-code (Robotic: connection to slave robotic failed in this example) is name of the component followed by the text description of the error sub-code. If you continue to have problems with a parallel SCSI Library, check the following: Ensure that the device is compatible with the parallel SCSI host adapter and backup application you plan to use.

He Cannot Initialize Barcode Reader Code 80 01

Generated Tue, 18 Oct 2016 00:15:36 GMT by s_ac15 (squid/3.5.20) ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.10/ Connection to 0.0.0.10 failed. DB External cooling fan error (fan motion has stopped). Based on the extent of the detection problem, check the following: If neither the application software nor operating system detects the tape drive, or they do not detect both the tape drive and the Library: Verify that all SAS cables are securely connected on both ends. Verify that an HBA is supported by the host computer and qualified with the Library.

Ensure that there is nothing obstructing the gripper. Please see Access holes for the right and left magazines. Check the cartridge for damage. He Elevator Blocked Code 8b 26 The log shows the Date/Time, Code, and Description.

Everything shows all events. Loop requires additional configuration. DB External cooling fan error. Based on the extent of the detection problem, check the following: If neither the application software nor operating system detects the tape drive, or they do not detect both the tape drive and the Library: Check the SCSI ID and change it if necessary.

If the Library is detected by the operating system, but is listed as an unknown or generic device: Make sure that the proper device driver, if applicable, is installed for the device. Hp Tape Library Error Codes Refer to the manuals supplied with the other devices on the parallel SCSI bus for information on enabling or disabling termination on those devices. Verify that the proper device driver is installed for the SAS host adapter. top Link for service and repair Click here to view information on Service and Repair .

He Slider Blocked Error During Second Slider Movement Code 8a 63

Update the Library to the latest version. Check the SAS connectors for bent pins or debris. He Cannot Initialize Barcode Reader Code 80 01 Robotic error sub-codes Sub-code Description 01 Mechanical initialization failure 02 Connection to slave robotic failed 03 Error motor initialization 04 Error during gripper close 05 Error slider home positioning 06 Error elevator home movement 07 Error during sled movement to rotation position 08 Error during rotation initialization, get range failed 09 Error elevator in it 0A Error during rotation to far position 0B Error first sled init, move to sensor failed 0C Error during sled movement to rotation position 0D Error during rotation to slide position 0E Error slider init, get range failed 0F Error during slider forward movement 10 Error gripper init, get range failed 11 Error during slider home movement 12 Error during rotation to FAR position 13 Error sled init, move to sensor failed 20 Error inventory scan 21 Error during gripper close 22 Error slider home movement 23 Error during move gripper to scan pos 24 Error reading bar code label 28 Error Extra inventory scan 29 Error during closing gripper 2A Error slider preposition movement 2B Error during opening gripper 2C Error during sled movement up to sensor 2D Error slider preposition backwards movement 30 Error slot preposition 31 Error during sled movement in FLMoveRotation 32 Command sending to robotic failed 33 Error during elevator movement in FLMoveRotation function 34 Error during rotation in FLMoveRotation function 35 Error during elevator movement in FLMoveRotation function 36 Error during sled movement in FLMoveSled function 37 Error during sled positioning to mailslot in FLMoveSled function 38 Error during sled positioning to mailslot in FLMoveSled function 39 Error during sled positioning without sensor 40 Movement to/from slot failed 41 Error during first slider movement 42 Error during first gripper movement 43 Error during second slider movement 44 Error during second gripper movement, get range failed 45 Error during third slider movement, move home failed 50 Preposition to drive failed 51 Elevator movement to home sensor failed 52 Sled movement to home sensor failed 53 Error during sled movement to drive position 54 Error during rotation to drive position 55 Error during elevator movement in drive position 60 Move from/to drive failed 61 Error during first slider movement 62 Error during first gripper movement 63 Error during second slider movement 64 Error during second gripper movement, get range failed 65 Error during third slider movement, move home failed 70 Release magazine failed 71 Error during sled movement to rotation position 72 Error during rotation to unlock position 73 Error during move sled to block 80 Opening mailslot failed 82 Error during moving back, sensor was found 90 Movement to home position failed 91 Elevator movement to home position failed 92 Error during sled movement to rotation position 93 Error during rotation to home or far position 94 Sled movement to home sensor position failed 95 Sled movement to transport position failed A0 Movement to mailslot failed A1 Sled movement to sensor failed A2 Sled movement to rotation position failed A3 Elevator movement to home position failed A4 Error during rotation to far position A5 Sled movement to mailslot position failed top Device error sub-codes The table below (Device error sub-codes) lists the device error sub-codes. He Elevator Blocked Error During Move Elevator To Scan Position Code 8b 26 If one of the ports on the device is not connected to another parallel SCSI device, the port must be terminated.

Thank you! his comment is here Power cycle the device and try again. There are three ways to obtain error codes from the device: On the OCP On the RMI On an L&TT support ticket or report top Finding error code information on the OCP Error codes are displayed in pop-up messages when an error occurs during an operation that is initiated from the operator control panel. Check if the fan is operational and not obstructed The error sub code will indicate which drive assembly is affected subcode 00 = Drive 1 subcode 01 = Drive 2 subcode 02 = Drive 3 subcode 03 = Drive 4 DC I2C bus failure Power-cycle the library F0 Drive exceeded temperature specification Check ambient temperature conditions and fans The error sub code will indicate which drive assembly is affected subcode 00 = Drive 1 subcode 01 = Drive 2 subcode 02 = Drive 3 subcode 03 = Drive 4 F1 Library controller lost communication with the drive Re-seat the tape drive The error sub code will indicate which drive assembly is affected subcode 00 = Drive 1 subcode 01 = Drive 2 subcode 02 = Drive 3 subcode 03 = Drive 4 F2 Drive sled5 not present F3 error Drive hardware Cycle power, after several occurrences Contact technical support The error sub code will indicate which drive assembly is affected subcode 00 = Drive 1 subcode 01 = Drive 2 subcode 02 = Drive 3 subcode 03 = Drive 4 F4 Time allotted for drive loading exceeded Retry the operation, if not successful Contact technical support The error sub code will indicate which drive assembly is affected subcode 00 = Drive 1 subcode 01 = Drive 2 subcode 02 = Drive 3 subcode 03 = Drive 4 F5 Time allotted for drive unloading exceeded Attempt Force Tape Eject test Inspect tape for defects after unloading The error sub code will indicate which drive assembly is affected subcode 00 = Drive 1 subcode 01 = Drive 2 subcode 02 = Drive 3 subcode 03 = Drive 4 top Error sub-code descriptions Robotic error sub-codes Robotic error sub-codes Sub-Code Description 01 Mechanical initialization failure 02 Connection to slave robotic failed 03 Error motor initialization 04 Error during gripper 1 close 05 Error slider 2 home positioning 06 Error elevator 3 home movement 07 Error during sled 5 movement to rotation 4 position 08 Error during rotation 4 initialization, get range failed 09 Error elevator 3 init 0A Error during rotation 4 to far position 0B Error first sled 5 init, move to sensor failed 0C Error during sled 5 movement to rotation 4 position 0D Error during rotation 4 to drive position 0E Error slider 2 init, get range failed 0F Error during slider 2 forward movement 10 Error gripper 1 init, get range failed 11 Error during slider 2 home movement 12 Error during rotation 4 to FAR position 13 Error sled 5 init, move to sensor failed 20 Error inventory scan 21 Error during gripper 1 close 22 Error slider 2 home movement 23 Error during move gripper 1 to scan pos 24 Error reading bar code label 28 Error Extra inventory scan 29 Error during closing gripper 1 2A Error slider 2 preposition movement 2B Error during opening gripper 1 2C Error during sled 5 movement up to sensor 2D Error slider 2 preposition backwards movement 30 Error slot preposition 31 Error during sled 5 movement in FLMoveRotation 32 Command sending to robotic failed 33 Error during elevator 3 movement in FLMoveRotation function 34 Error during rotation 4 in FLMoveRotation function 35 Error during elevator 3 movement in FLMoveRotation function 36 Error during sled 5 movement in FLMoveSled function 37 Error during sled 5 positioning to mail slot in FLMoveSled function 38 Error during sled 5 positioning to mail slot in FLMoveSled function 39 Error during sled 5 positioning without sensor 40 Movement to/from slot failed 41 Error during first slider 2 movement 42 Error during first gripper 1 movement 43 Error during second slider 2 movement 44 Error during second gripper 1 movement, get range failed 45 Error during third slider 2 movement, move home failed 50 Preposition to drive failed 51 Elevator 3 movement to home sensor failed 52 Sled 5 movement to home sensor failed 53 Error during sled 5 movement to drive position 54 Error during rotation 4 to drive position 55 Error during elevator 3 movement in drive position 60 Move from/to drive failed 61 Error during first slider 2 movement 62 Error during first gripper 1 movement 63 Error during second slider 2 movement 64 Error during second gripper 1 movement, get range failed A4 Error during rotation 4 to far position 65 Error during third slider 2 movement, move home failed 70 Release magazine failed 71 Error during sled 5 movement to rotation 4 position 72 Error during rotation 4 to unlock position 73 Error during move sled 5 to block 80 Opening mail slot failed 82 Error during moving back, sensor was found 90 Movement to home position failed 91 Elevator 3 movement to home position failed 92 Error during sled 5 movement to rotation 4 position 93 Error during rotation 4 to home or far position 94 Sled 5 movement to home sensor position failed 95 Sled 5 movement to transport position failed A0 Movement to mail slot failed A1 Sled 5 movement to sensor failed A2 Sled 5 movement to rotation position failed A3 Elevator 3 movement to home position failed A4 Error during rotation 4 to far position A5 Sled 5 movement to mail slot position failed NOTE: Gripper is the part of the robotics assembly that pinches media in order to grip it. He Sled Position Not Found Code 9b 37

D1 RAM error during Power-On-Self-Test Power-cycle the unit D2 Read or Write to NVRAM on Library controller failed D3 Time controller failed during Power-On-Self-Test D4 Internal UART serial communication error D5 Communication to display failed D6 Library controller memory error D7 Fatal system error D8 Library controller data base error D9 No SCSI IC detected DA When running the wellness test, the bar code did not match the previous value for that tape Check the bar code label for proper application and damage. If the failure follows the tape cartridge, the tape cartridge may be at fault. A data cartridge may have been loaded instead of a cleaning cartridge. http://orgias.org/error-codes/hp-storageworks-msl2024-error-codes.html NOTE: For an online troubleshooting tool, go to www.hp.com/support/MSLG3Tstree .

Check if the fan is operational and not obstructed DC I2C Bus failure. Mechanical Block Code 8d 07 Ibm Ensure that the device is either mounted in a rack with its rack kit or in a tabletop conversion cover. Do not use a cable adapter or converters between the HBA and the Library.

Also access error information from the Support sub-menu item, see Viewing logs (Support > View Logs) .

Attempt the Force Tape Eject process. Here are some terms that you would encounter in the table below (Robotic error sub-codes): Gripper: The part of the robotics assembly that pinches media in order to grip it. Fourth code - Sub-code-specific information for factory use only Figure 1: Support: Library logs page top Finding error code information on an L&TT support ticket or report An L&TT support ticket or report contains detailed information about the device configuration, along with errors and warnings. Ibm Ts3200 Error Codes If the error persists, contact support personnel, visit www.hp.com/support .

Does the operating system detect the tape drive? The support ticket can be downloaded from the device and then viewed on any computer with L&TT installed. For reliable operation, do not use a SAS cable longer than six meters. http://orgias.org/error-codes/hp-msl4048-mechanical-block-error.html The system returned: (22) Invalid argument The remote host or network may be down.