Home > Error Codes > Hp Msl4048 Mechanical Block Error

Hp Msl4048 Mechanical Block Error

Contents

Remove the magazines, re-seat them, and try again. For example, 1:00 pm is 13:00.D7 is the main error code50 is the error sub-code top Finding error code information on the RMI You can find error codes on the RMI Support: Library Logs page. Put the magazine(s) back into the library (preferably empty),and power on the library. Once the original LCC is installed and the library is powered on, the VPD will be copied from the LCB to the replacement chassis’ picker. Source

Power down the Library and re-seat the library controller from the back panel. The log entries are displayed in order of most recent to oldest. Ja Nein Schicken Sie uns Ihr Feedback. The shipping lock has been removed - which is the only suggestion I've been able to find. http://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c00768254

Msl4048 Error Codes

This thread has been movedfrom Tape Backup (Small and Medium Business) to Tape Libraries and Drives - Hp Forums Moderator 1 person had this problem. 0 Kudos Reply All Forum Topics Previous Topic Next Topic 1 REPLY Curtis Ballard Honored Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Storage > Tape > Tape Libraries and Drives > MSL 4048 Mechanical Block Community Tape Libraries and Drives CommunityCategoryBoardUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type. F0 Drive exceeded temperature specification Check ambient temperature to ensure that it is within operating specifications. F4 Time allotted for drive loading exceeded Check that the tape cartridge is supported and has not exceeded its usage life. If it is a new or moved tape library, has the shipping lockhas been removed?

The support ticket can be downloaded from the device and then viewed on any computer with L&TT installed. paris: Use a .cer certificate not .CRT Malcolm: Mate You are a time-saver. It's a little annoying always having old errors that weren't serious there but I've gotten used to it. 0 Kudos Reply The opinions expressed above are the personal opinions of the authors, not of Hewlett Packard Enterprise. He Sled Position Not Found Code 9b 37 Click the Health button on the main toolbar to generate and display a standard report or click the Support button on the main toolbar to display the Support screen for additional report or support ticket options.

Very helpful Somewhat helpful Not helpful End of content United StatesHewlett Packard Enterprise International Start of Country Selector content Select Your Country/Region and Language Click or use the tab key to select your country ArgentinaAustraliaBelgiqueBoliviaBrasilCanadaCanada-françaisČeská republikaChileColombiaDeutschlandEcuadorEspañaFranceIndiaIrelandItaliaMagyarországMéxicoNew ZealandÖsterreichParaguayPerúPolskaPortugalPuerto RicoSchweizSouth AfricaSuisseTürkiyeUnited KingdomUnited StatesUruguayVenezuelaΕλλάδαРоссия中国台灣日本香港대한민국 End of Country Selector content AmericasAsia and OceaniaEurope, Middle East and AfricaClose Country Selector dialog CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner ProgramsSocialSocialLinkedInFacebookTwitterYouTubeCommunitiesCommunitiesDeveloper ForumsEnterprise BusinessCustomer ResourcesCustomer ResourcesEnterprise StorePublic Sector StoreEducation and TrainingEmail SignupLegalLegalPrivacyTerms of UseCookies © Copyright 2016 Hewlett Packard Enterprise Development LP Skip to ContentSkip to FooterSolutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility Infrastructure Internet of Things Small and Medium Business Service Providers All Solutions Services Advise, Transform and Manage Financing and Flexible Capacity IT Support Services Education and Training Services All Services Products Integrated Systems Composable Systems Converged Systems Hyper Converged Systems Blade Systems Infrastructure Management Software Application Lifecycle Management Application Delivery Management Big Data Analytics DevOps Enterprise Security Hybrid and Private Cloud Information Governance Information Management IT Service Management Operations Management Server Management Software as a Service (SaaS) Software-Defined Data Center Storage Management All Software Servers Rack Servers Tower Servers Blade Servers Density Optimized Mission Critical Servers Servers for Cloud Server Management All Servers Storage All-flash and Hybrid Storage Midrange and Enterprise Storage Entry Storage Systems Data Availability, Protection and Retention Software Defined Storage Management and Orchestration Storage Networking All Storage Networking Switches Routers Access Points and Controllers Wireless LAN Campus and Branch Networking Data Center Networking Wide Area Network Software Defined Networking Network Functions Virtualization Network Management All Networking About UsSupportClearType to search2086159Solutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility Infrastructure Internet of Things Small and Medium Business Service Providers All Solutions Services Advise, Transform and Manage Financing and Flexible Capacity IT Support Services Education and Training Services All Services Products Integrated Systems Composable Systems Converged Systems Hyper Converged Systems Blade Systems Infrastructure Management Software Application Lifecycle Management Application Delivery Management Big Data Analytics DevOps Enterprise Security Hybrid and Private Cloud Information Governance Information Management IT Service Management Operations Management Server Management Software as a Service (SaaS) Software-Defined Data Center Storage Management All Software Servers Rack Servers Tower Servers Blade Servers Density Optimized Mission Critical Servers Servers for Cloud Server Management All Servers Storage All-flash and Hybrid Storage Midrange and Enterprise Storage Entry Storage Systems Data Availability, Protection and Retention Software Defined Storage Management and Orchestration Storage Networking All Storage Networking Switches Routers Access Points and Controllers Wireless LAN Campus and Branch Networking Data Center Networking Wide Area Network Software Defined Networking Network Functions Virtualization Network Management All Networking About UsSupport Start of content Community Home > Storage > Tape > Tape Libraries and Drives > MSL4048 "MECHANICAL BLOCK" amber light error Community Tape Libraries and Drives CommunityCategoryBoardUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type. He: Elevator Blocked, Error During Move Elevator To Scan Position Code: 8b 26 The text after the main error code (Robotic controller generic problem in this example) is the text description for the error code. Artikel-ID: SLN155569 Datum der letzten Änderung: 06/21/2013 12:00 AM Diesen Artikel bewerten Präzise Nützlich Leicht verständlich War dieser Artikel hilfreich? I haven't had any issues until today.I was importing a tape, through the mail slot.

Library error sub-codes The following table lists the library error sub-codes. Hp Tape Library Error Codes Error during sled movement to rotation position. This will exclude media being the cause. If not, the shipping lock is locatedon top of the library.

He: Elevator Blocked, Error During Move Elevator To Scan Position Code: 8b 26

The format for the log entries is: YY.MM.DD HH.MM.SS.ss LIB/ERR<80 89 62 40 YY.MM.DD - The date displayed as Year.Month.Day HH.MM.SS.ss - The time displayed as Hour.Minute.Second.Hundredths fo a second First code - Hard or soft error. https://community.hpe.com/t5/Tape-Libraries-and-Drives/Tape-Drive-Mechanical-Block-8A-41-error/td-p/4468583 Please consult your web browser's help section to turn-off this feature, if necessary. 

Quick Tips content is self-published by the Dell Support Professionals who resolve issues daily. Msl4048 Error Codes Slider: The part of the robotics assembly that plunges in and out for get and put operations. He Slider Blocked Error During Second Slider Movement Code 8a 63 Inspect it for damage.

The wellness test exercises all robotic movements and checks the status of the electrical components and communication. A1 Open Mail Slot failed Retry the operation If not successful, contact technical support B0 Command from library controller to robotics controller didn’t complete in time allotted Reset the unit Retry the operation If not successful, contact technical support B1 Robot controller reported format error on command from library controller B2 Communication to robot from library controller failed B3 Robot stopped due to a released magazine Check if magazine is completely inserted Retry the operation If not successful, contact technical support B4 Tape in gripper sensor did not report the expected value NOTE: Gripper is the part of the robotics assembly that pinches media in order to grip it. What does this error mean? 0 Kudos Reply All Forum Topics Previous Topic Next Topic 2 REPLIES Curtis Ballard Honored Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎04-10-2009 09:03 AM ‎04-10-2009 09:03 AM Re: MSL 4048 Mechanical Block Error 8A 45 That is an error code for unable to pull a tape completely into the transport. It uniquely maps to an error code. Mechanical Block Code 8d 07 Ibm

Yours Sincerely, HP Global Delivery, Technology Services" P.S. To run the wellness test from the OCP, see the Running tests (Support > Run Tests) section in Operator Control Panel (OCP) . Typical Steps for TL2000 / TL4000 Mechanical Errors: If the tape library is new or has been moved, make sure the shipping lock has been removed from the top of the library. have a peek here Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking Servers and Operating Systems Software Services Storage Company Careers Corporate Responsibility Events Hewlett Packard Labs Partner Certification Partner Solutions Welcome Welcome Announcements Tips and Tricks Feedback Blogs All About the Apps Alliances Around the Storage Block Backup and Governance Behind the scenes @ Labs Big Data Cloud Source Coffee Coaching Converged Data Center Infrastructure Discover Insider Enterprise Services Grounded in the Cloud HPE Business Insights HPE Careers Infrastructure Insights Inspiring Progress Internet of Things (IoT) Solutions from HPE IT Operations Management (ITOM) IT Service Management LoadRunner and Performance Center My Learning Certification Networking OEM Solutions Protect Your Assets Security Research Servers: The Right Compute Software Developers Software Solutions Technical Support Services Telecom IQ Transforming IT UK Public Sector Voice of the Customer – Interviews by Dana Gardner Quick Links Community FAQ Community FAQ - Quick Start FAQ - Registration and Logging In FAQ - Community Search FAQ - Blogs FAQ - Kudos FAQ - Accepted Solutions FAQ - Images and Image Galleries FAQ - Tagging FAQ - Bookmarks, Subscriptions, and RSS FAQ - Personalize Your Account Settings FAQ - Private Messenger Community Guidelines Contact Us Community FAQ - Quick Start Ranking Overview Rules of Participation Tell us what you think HPE Developer Community HPE Live Network Content Marketplace HPE Software Support Online HPE Support Center Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking Servers and Operating Systems Software Services Storage Company Careers Corporate Responsibility Events Hewlett Packard Labs Partner Certification Partner Solutions Welcome Welcome Announcements Tips and Tricks Feedback Blogs All About the AppsAlliancesAround the Storage BlockBackup and GovernanceBehind the scenes @ LabsBig DataCloud SourceCoffee CoachingConverged Data Center InfrastructureDiscover InsiderEnterprise ServicesGrounded in the CloudHPE Business InsightsHPE CareersInfrastructure InsightsInspiring ProgressInternet of Things (IoT) Solutions from HPEIT Operations Management (ITOM)IT Service ManagementLoadRunner and Performance CenterMy Learning CertificationNetworkingOEM SolutionsProtect Your AssetsSecurity ResearchServers: The Right ComputeSoftware DevelopersSoftware SolutionsTechnical Support ServicesTelecom IQTransforming ITUK Public SectorVoice of the Customer – Interviews by Dana Gardner Quick Links Community FAQ Community FAQ - Quick Start FAQ - Registration and Logging In FAQ - Community Search FAQ - Blogs FAQ - Kudos FAQ - Accepted Solutions FAQ - Images and Image Galleries FAQ - Tagging FAQ - Bookmarks, Subscriptions, and RSS FAQ - Personalize Your Account Settings FAQ - Private Messenger Community Guidelines Contact Us Community FAQ - Quick Start Ranking Overview Rules of Participation Tell us what you think HPE Developer Community HPE Live Network Content Marketplace HPE Software Support Online HPE Support Center Log In English English Deutsch Español Française Italiano 한국어 日本語 Norsk Português Русский 简体中文 繁體中文 New Post Tape Drive Mechanical Block 8A 41 error Topic Options Subscribe to RSS Feed Mark Topic as New Mark Topic as Read Float this Topic to the Top Bookmark Subscribe Printer Friendly Page SBailey Occasional Contributor Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎07-28-2009 01:43 PM ‎07-28-2009 01:43 PM Tape Drive Mechanical Block 8A 41 error Hi,I have a HP StorageWorks 1/8 G2 Autoloader (using an LTO3 drive).

Figure 2: Support ticket in viewer Expand HP Event Logs to see events divided into three categories: Events in the last 24 hours Events in the last 31 days Events older than 31 days Set the Current Detail Level to see additional types of events: Normal will only show critical events or hard errors. He Cannot Initialize Barcode Reader Code 80 01 Expand the event for more information (as shown in Figure 3). Slider is the part of the robotics assembly that plunges in and out for get and put operations.

If the firmware for the tape library and / or tape drive areout-of-date, please update the firmware, if possible.Use the following links:PowerVault TL2000 / TL4000 Tape Library - How to Check the Firmware Revisions for the Tape Library and Tape DrivesPowerVault TL2000 / TL4000 Tape Library - How to Upgrade the Firmware for the Tape Library and Tape Drives If there is a possible obstruction within the library, one couldtry the following: If it is media related, such as a tape in the driveor a magazine slot - try to move the tape to a slot or another slotusing the RMU or OCP.RMU (Preferred) - Manage Library, Move Media, select Source, select Destination, click MoveOCP - Control, Move Cartridges, Source Type, Source, Dest, Dest Type Stop the backup software services on the server that the library is attached to, if it has not already been done so.

If the failure remains with the same slot, the magazine may be at fault. To run the wellness test from the RMI, see the Performing general diagnostics section in Remote Management Interface (RMI) . Select the support ticket file in the browser. Ibm Ts3200 Error Codes B0 Command from Library controller to robotics controller did not complete in time allotted Reset the device and retry the operation.

Rotation: The part of the robotics assembly that turns the robot to face each magazine and the drive. If there is a tape in the robot, replace the magazines and power-cycle the device. top Link for troubleshooting Click here to view information on Troubleshooting . Power on the library, and wait for it initialize completely.Sometimes, performing this step will move the tape that is causing the issue.

If the failure remains with the same slot, the magazine may be at fault. Arash: Hi, I follow the instructions you provided and now it's asking me "PKCS12/PFX format requires... For example: 8D 52 Mechanical Block The error log contains a list of all errors, with a separate row for each error. B1 Robot controller reported format error on command from Library controller Reset the device and retry the operation.

Upgrading the Library firmware might resolve this issue. Check if the fan is operational and not obstructed The error sub code will indicate which drive assembly is affected subcode 00 = Drive 1 subcode 01 = Drive 2 subcode 02 = Drive 3 subcode 03 = Drive 4 DC I2C bus failure Power-cycle the library F0 Drive exceeded temperature specification Check ambient temperature conditions and fans The error sub code will indicate which drive assembly is affected subcode 00 = Drive 1 subcode 01 = Drive 2 subcode 02 = Drive 3 subcode 03 = Drive 4 F1 Library controller lost communication with the drive Re-seat the tape drive The error sub code will indicate which drive assembly is affected subcode 00 = Drive 1 subcode 01 = Drive 2 subcode 02 = Drive 3 subcode 03 = Drive 4 F2 Drive sled5 not present F3 error Drive hardware Cycle power, after several occurrences Contact technical support The error sub code will indicate which drive assembly is affected subcode 00 = Drive 1 subcode 01 = Drive 2 subcode 02 = Drive 3 subcode 03 = Drive 4 F4 Time allotted for drive loading exceeded Retry the operation, if not successful Contact technical support The error sub code will indicate which drive assembly is affected subcode 00 = Drive 1 subcode 01 = Drive 2 subcode 02 = Drive 3 subcode 03 = Drive 4 F5 Time allotted for drive unloading exceeded Attempt Force Tape Eject test Inspect tape for defects after unloading The error sub code will indicate which drive assembly is affected subcode 00 = Drive 1 subcode 01 = Drive 2 subcode 02 = Drive 3 subcode 03 = Drive 4 top Error sub-code descriptions Robotic error sub-codes Robotic error sub-codes Sub-Code Description 01 Mechanical initialization failure 02 Connection to slave robotic failed 03 Error motor initialization 04 Error during gripper 1 close 05 Error slider 2 home positioning 06 Error elevator 3 home movement 07 Error during sled 5 movement to rotation 4 position 08 Error during rotation 4 initialization, get range failed 09 Error elevator 3 init 0A Error during rotation 4 to far position 0B Error first sled 5 init, move to sensor failed 0C Error during sled 5 movement to rotation 4 position 0D Error during rotation 4 to drive position 0E Error slider 2 init, get range failed 0F Error during slider 2 forward movement 10 Error gripper 1 init, get range failed 11 Error during slider 2 home movement 12 Error during rotation 4 to FAR position 13 Error sled 5 init, move to sensor failed 20 Error inventory scan 21 Error during gripper 1 close 22 Error slider 2 home movement 23 Error during move gripper 1 to scan pos 24 Error reading bar code label 28 Error Extra inventory scan 29 Error during closing gripper 1 2A Error slider 2 preposition movement 2B Error during opening gripper 1 2C Error during sled 5 movement up to sensor 2D Error slider 2 preposition backwards movement 30 Error slot preposition 31 Error during sled 5 movement in FLMoveRotation 32 Command sending to robotic failed 33 Error during elevator 3 movement in FLMoveRotation function 34 Error during rotation 4 in FLMoveRotation function 35 Error during elevator 3 movement in FLMoveRotation function 36 Error during sled 5 movement in FLMoveSled function 37 Error during sled 5 positioning to mail slot in FLMoveSled function 38 Error during sled 5 positioning to mail slot in FLMoveSled function 39 Error during sled 5 positioning without sensor 40 Movement to/from slot failed 41 Error during first slider 2 movement 42 Error during first gripper 1 movement 43 Error during second slider 2 movement 44 Error during second gripper 1 movement, get range failed 45 Error during third slider 2 movement, move home failed 50 Preposition to drive failed 51 Elevator 3 movement to home sensor failed 52 Sled 5 movement to home sensor failed 53 Error during sled 5 movement to drive position 54 Error during rotation 4 to drive position 55 Error during elevator 3 movement in drive position 60 Move from/to drive failed 61 Error during first slider 2 movement 62 Error during first gripper 1 movement 63 Error during second slider 2 movement 64 Error during second gripper 1 movement, get range failed A4 Error during rotation 4 to far position 65 Error during third slider 2 movement, move home failed 70 Release magazine failed 71 Error during sled 5 movement to rotation 4 position 72 Error during rotation 4 to unlock position 73 Error during move sled 5 to block 80 Opening mail slot failed 82 Error during moving back, sensor was found 90 Movement to home position failed 91 Elevator 3 movement to home position failed 92 Error during sled 5 movement to rotation 4 position 93 Error during rotation 4 to home or far position 94 Sled 5 movement to home sensor position failed 95 Sled 5 movement to transport position failed A0 Movement to mail slot failed A1 Sled 5 movement to sensor failed A2 Sled 5 movement to rotation position failed A3 Elevator 3 movement to home position failed A4 Error during rotation 4 to far position A5 Sled 5 movement to mail slot position failed NOTE: Gripper is the part of the robotics assembly that pinches media in order to grip it. Check all fans to determine whether they are working properly. After the replacement chassis is installed, remove the LCC that came with the replacement chassis and insert the LCC from the original library chassis.

Kitts und Nevis St. Lucia St. See the Force ejecting a drive (Support > Force Drive Eject) section in Operator Control Panel (OCP) . The message shows the error code and a description of the error.

Any activity that exercises (uses) the library's picker results in a Mechanical error message.The library may also report an unusual status for the tape drives suchas "Unsupported" or "Writing" in the Remote Management Unit, or Web Interface.Additionally, the Display or Operator Control Panel (OCP) remains on the pre-initialization status screen that shows the library firmware revision, number of tape drives, etc. Everything shows all events. For example, in this case 14 is 2 p.m. Notify me of new posts by email.

sub-code 00: drive sled #1, sub-code 01: drive sled #2 NOTE: Sled is the part of the robotics assembly that moves the robot towards the OCP or back towards the drive.